DR HUGO McQ A3 Refrigerated Air Dryer | High Efficiency Air Cooling & Drying System for Hyperbaric Chambers

Features:
1). The interior space is spacious without feeling oppressive, Suitable for claustrophobic users.
2) . The cabin is firm and can be decorated according to your own preferences.
2) . Interphone system for two-way communication.
3) . Automatic air pressure control system, the door is sealed by pressure.

    This is a paragraph






    McQ A3 air cooler is an electronically cooled gas condenser. It is used to cool and dry high-temperature, humid gases, reducing the water content of the sample gas. It employs freeze-drying technology and is primarily used at the point of use to dry and purify the gas source, achieving gas-liquid separation. This device is mainly used in various gas pretreatment systems. It can lower the gas dew point and reduce the problem of water in the gas affecting downstream equipment. This product uses precise temperature control; the temperature is regulated by an intelligent module, keeping the cold chamber temperature constant at the set temperature, with a temperature accuracy of ±0.1℃. The drainage device operates cyclically with a controllable time of 0-9999 seconds. Precautions: Ensure good ventilation at both the top and bottom ends and the front cooling fan during installation. There should be no heat sources nearby, and a 100mm space should be left on both sides. Keep the equipment level during installation and use, and pay attention to collecting condensed water. Instructions for Use: Before starting and commissioning the equipment, check that all gas connections are leak-free and ensure the power connection is correct. Connect the power supply, and the equipment will start. After a few minutes of operation, the dew point will decrease, reaching a stable state in about 20 minutes (depending on the ambient temperature). Panel Operation and Parameter Settings: This device allows you to set the control target temperature and drainage valve operating parameters on the control panel. Temperature setting: Press SET, P1 drainage valve working time, P2 drainage valve stop time, P3 temperature hysteresis, P4 cold chamber temperature, P5 cold chamber over-temperature signal (this function requires customization), P6 cold chamber protection temperature (the device will not operate if the cold chamber temperature is higher than this set temperature). Use the up and down keys to adjust the corresponding parameters. Temperature setting range: 0~20℃, time unit: seconds. Drainage setting: 0-9999 seconds. TEST button for manual drainage: Pressing the TEST button will activate the drainage valve for 10 seconds, after which it will continue to operate according to the set cycle time. Maintenance: Regularly clean dust and foreign objects from the condenser's heat dissipation surface to maintain good ventilation and heat dissipation. #aircooler #cooler #condenser #dehumidifier #hbot #hbotusa





    Picture

    McQ A3 (1)McQ A3 (1)
    McQ A3 (2)how to connect
    Recommend Soft Chamber Models 019h1Recommend Soft Chamber Models 020ax