6 parameter vital signs monitor with touch screen uMR P11+

Bedside monitor -with touch screen

parameter:ECG+SPO2+ NIBP+TEMP+RESP+PR

6 parameter vital signs monitor with touch screen

Optional parameters:

Printer, ETCO2,2-IBP


Product Detail

Product Tags

Features &Benefits:

  1. 12.1” color TFT display, high resolution: 800×600dpi;
  2. Separated para board: ECG, NIBP, SpO2 board;
  3. Full touch-screen enables intuitive operation by clicking one the specific parameters or the
  4. waveform in real time, standard configuration includes the navigation knob.
  5. Real time S-T segment analysis, and ARR analysis;
  6. SpO2 Pitch Tone Variation and Drug Dose Calculation;
  7. Parameter waveform and characters color selectable
  8. Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic
  9. Standby mode for Energy saving and suspend monitoring;
  10. 7-lead ECG waveforms display in phase;
  11. Capture dynamic waveforms;
  12. Built-in rechargeable lithium battery, and battery volume checking,
  13. AC power checking
  14. Efficient resistance to interference of defibrillator and HF knife;
  15. SINNOR F-6 SpO2 technology, VS NELLCOR accuracy;
  16. Networking capacity and TCP/IP networking platform enable abundant future upgrade
  17. Time delay switch-off function keep the monitor data restart monitor;
  18. Complete and flexible mounting solution for transportation and in-patient monitoring

 

Standard parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR.

Optional: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo

SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO,

Performance Specifications

Display: 12.1”color TFT

Rolling and refreshing waveform display

Resolution: 800×600

Multi display selectable including:

Large-font display

Trend coexist display

OxyCRG dynamic view display.

Bed-to-bed view display

Trace: 7 waveforms (5 ECG, 1 SPO2 and 1 RESP)

Sweep speed: 6.25mm/s, 12.5mm/s,25mm/s,50mm/s

Indicator: Power/battery indicator light

QRS beep and alarm sound

Battery: Rechargeable lead acid cell, 12v/4AH

Max.24 hour for charging, 4 hours for continue working

Trend: Parameter graphic and tabular trends:

5s/piece, 8 hours;

1min/piece,168 hours(24hour×7days)

5min/piece, 1000 hours.

Storage:           NIBP: 1000 groups

Alarm: 200 groups

Full disclosure waveforms: 3600S

Alarm:                   User-adjustable High, Medium and Low limits 3-level Audible and visual alarm

Networking:          Connected to central monitoring system

TCP/IP netting platform

Recorder:              Build-in, thermal array

Plethysmogram caveform: 2 channels

Record mode: manual, on alarm, time-defined

Recording width: 50mm

Printing speed: 50mm/s

Recording type:          Frozen waveform record

NIBP recall record

Trend table record

Alarm record

Fixed -time record

Standard parameter:

ECG:

Lead mode: 5 –lead(R,L,F,N,C)

Lead selection : I,II,III,avR,avL,avF,V

Waveform: 3 and 7 channel selectable

Gain selection:0.5mm/mv,1mm/mv,2mm/mv

Sweep speed:12.5mm/s;25mm/s;50mm/s

Heart rate range: Adult: 15~300bpm; Neonate:/pediatric:15~350bpm

Accuracy: +1bpm or +1%, whichecer is greater

Resolution: 1bpm

Filter:
surgery mode:1~20Hz

monitor model:0.5~40Hz

Diagnostic mode:0.05~130Hz

Scaling signal: 1mv,+3%

Protection:  withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation

Alarm range: 15~350bpm

S-T segment detection:        

Measurement range:  2.0mV~+2.0mV                         

AlarmRange: -2.0mV~ +2.0mV

Accuracy: -0.8mV ~+0.8Mv

Error: +0.02Mv

Arrhythmia analysis: YES

RESPIRATION

Method: Thoracic impedance

Measurement range: Adult:7~120rpm;

Neonate/Pediatric:7~150rpm

Apnea alarm: YES,10~40s

Resolution:  1rpm

Accuracy:+2rpm

TEMPERATURE

Compatible probe: YSI or CYF

Measurement range: 5~50℃

Resolution :  0.1℃

Accuracy:  +0.1℃

Refreshing time:  about 1

Average measuring time:  <10s

SPO2:

Measurement range: 0~100%

Resolution: 1%

Accuracy: +2%(70-100%);0-69% unspecified

Alarm range :0~100%

Pulse Rate: range: 20~300bpm

Resolution: 1bpm

Error:+1bpm or +2%,whichever is greater

Method: Digital Automatic oscillometric

Operation mode : Manual/Automatic/continuous

Auto measurement time:Adjustable(1~480min)

Measurement Unit: mmHg/Kpa selectable

Measurement types: Systolic, Diastolic, Mean 

Measurement range:

Range of Systolic pressure:

Adult: 40~270mmHg

Pediatric: 40~220mmHg

Neonate: 40~135mmHg

Range of mean pressure: 

Adult: 20~235mmHg

Pediatric: 20~165mmHg

Neonate: 20~110mmHg

Range of diastolic pressure:  

Adult: 10~215mmHg

Pediatric: 10~150mmHg

Neonate :10~100mmHg

Over-pressure protection: Double safety protection

Resolution: 1 mmHg

Alarm: Systolic, Diastolic, Mean

Miscellaneous

Safety:              

Safety level: Class I, type CF

Operation Environment

Temperature: Working 0~+40℃

Transportation and storage –20~+60℃

Humidity: working≤85%

Transportation and storage≤93%

Power: AC 100-240,50/60Hz

Patient range:   Neonate, pediatric, adult patients

Accessories supplies

(1) 5 lead ECG cable 

(2) 1 spo2 probes 

(3) 1 NIBP probe 

(4) 1 temp probe

(5)1 ground connecting liner 

(6) Chest electrode (10pcs/set)

 Dimension and Weight

Dimension:    37*21*43CM

G.W.:        5.5KS

P11详情页  (3)

  • Previous:
  • Next:

  • Write your message here and send it to us