12.1-inch Multi - Parameter ECG Monitor with Color Screen and Network Function for Patient Monitoring uMR N15
Specification
| Standard parameters: | 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR. |
| Optional: | Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO, |
| Display: | 12.1”color TFT |
| Rolling and refreshing waveform display | |
| Resolution: 800×600 | |
| Multi display selectable including: | |
| Large-font display | |
| Trend coexist display | |
| OxyCRG dynamic view display. | |
| Bed-to-bed view display | |
| Trace: | 9 waveforms(7 ECG, 1 SPO2 and 1 RESP) |
| Sweep speed:12.5mm/s,25mm/s,50mm/s | |
| Indicator: | Power/battery indicator light |
| QRS beep and alarm sound | |
| Battery: | Rechargeable lead acid cell, 12v/4AH |
| Max.24 hour for charging, 4 hours for continue working | |
| Trend: | Parameter graphic and tabular trends: |
| 5s/piece, 8 hours; | |
| 1min/piece,168 hours(24hour×7days) | |
| 5min/piece,1000 hours. | |
| Storage: | NIBP: 1000 groups |
| Alarm: 200 groups | |
| Full disclosure waveforms: 3600S | |
| Alarm: | User-adjustable High, Medium and Low limits 3-level Audible and visual alarm |
| Networking: | Connected to central monitoring system |
| TCP/IP netting platform | |
| Recorder: | Build-in, thermal array |
| Plethysmogram caveform:2 channels | |
| Record mode: manual, on alarm, time-defined | |
| Recording width: 50mm | |
| Printing speed: 50mm/s | |
| Recording type: | Frozen waveform record |
| NIBP recall record | |
| Trend table record | |
| Alarm record | |
| Fixed -time record |
Standard parameter:
ECG:
| Lead mode: | 5 –lead(R,L,F,N,C) |
| Lead selection : | I,II,III,avR,avL,avF,V |
| Waveform: | 3 and 7 channel selectable |
| Gain selection: | 0.5mm/mv,1mm/mv,2mm/mv |
| Sweep speed: | 12.5mm/s;25mm/s;50mm/s |
| Heart rate range: | Adult: 15~300bpm; |
| Neonate/pediatric:15~350bpm | |
| Accuracy: | .+1bpm or +1%,whichecer is greater |
| Resolution: | 1bpm |
| Filter: | surgery mode:1~20Hz |
| monitor model:0.5~40Hz | |
| Diagnostic mode:0.05~130Hz | |
| Scaling signal: | 1mv,+3% |
| Protection: | withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation |
| Alarm range: | 15~350bpm |
| S-T segment detection: | |
| Measurement range: | 2.0mV~+2.0mV |
| Alarm Range: | . -2.0mV~ +2.0mV |
| Accuracy: | . -0.8mV ~+0.8Mv |
| Error: | .+0.02Mv |
| Arrhythmia analysis: | YES |
SPO2:
| Measurement range: | 0~100% |
| Resolution: | 1% |
| Accuracy: | .+2%(70-100%);0-69% unspecified |
| Alarm range : | 0~100% |
| Pulse Rate: | range: 20~300bpm |
| Resolution:1bpm | |
| Error: +1bpm or +2%,whichever is greater |
NIBP:
| Method: | Digital Automatic oscillometric |
| Operation mode : | Manual/Automatic/continuous |
| Auto measurement time: | Adjustable(1~480min) |
| Measurement Unit: | mmHg/Kpa selectable |
| Measurement types: | Systolic, Diastolic, Mean |
| Measurement range: | |
| Range of Systolic pressure: | Adult: 40~270mmHg |
| Pediatric: 40~220mmHg | |
| Neonate: 40~135mmHg | |
| Range of mean pressure: | Adult: 20~235mmHg |
| Pediatric: 20~165mmHg | |
| Neonate: 20~110mmHg | |
| Range of diastolic pressure: | Adult: 10~215mmHg |
| Pediatric: 10~150mmHg | |
| Neonate :10~100mmHg | |
| Over-pressure protection: | Double safety protection |
| Resolution: | 1 mmHg |
| Alarm: | Systolic, Diastolic, Mean |
RESPIRATION:
| Method: | Thoracic impedance |
| Measurement range: | Adult:7~120rpm; |
| Neonate/Pediatric:7~150rpm | |
| Apnea alarm: | YES,10~40s |
| Resolution: | 1rpm |
| Accuracy: | . +2rpm |
TEMPERATURE:
| Compatible probe: | YSI or CYF |
| Measurement range: | 5~50℃ |
| Resolution : | 0.1℃ |
| Accuracy: | .+0.1℃ |
| Refreshing time: | about 1 |
| Average measuring time: | <10s |