Specification
Index
Content
Type
Automatic External Defibrillator
Model
uDEF 7000
Defibrillator
Category
Specification
Output
Biphasic Truncated exponential
Energy Sequence
150,150,200J
Charge Time
8 sec.to 150J
10 sec. to 200 J (New battery)
Analysis Time
9 sec.
The maximum time from the initiation of rhythm
Less than 20 seconds
analysis to readiness for discharge with a new battery.
The maximum time from the initiation of rhythm
Less than 25 seconds
analysis to readiness for discharge after 6 shocks.
The maximum time from initially switching power on to readiness for discharge.
Less than 30 seconds
Audible Prompts
22 audible prompts
Visual Prompts
LED prompts; Automatic Self-test
Controls
Two buttons - On/Off, Shock
Output Energy Accuracy
+-15% into any impedance from 25 to 1750
The Maximum Voltage
1200+-50V
Output disabled when the patient impedance is outside limits
202 to 200Q
Battery
Part No
CR123A-4x2
Non-rechargeable
2.8 Ah
Capacity
100 discharges at 200 Joules or 120 discharges at 150 Joules
Shelf Life(25C15C)
5 years standby (after installation)
Physical
Dimensions
303 x 216 x 89 mm
Weight
2.0 kg
Operating Temperature
0C to 40C
Operating Humidity
Relative humidity between 30% and 95%
(non-condensing)
Storage Temperature
-20C to 55C
(without battery)
Storage Humidity
Up to 93%(non-condensing)
(without battery)
| Index | Content |
| Type | Automatic External Defibrillator |
| Model | uDEF 7000 |
| Defibrillator | |
| Category | Specification |
| Output | Biphasic Truncated exponential |
| Energy Sequence | 150,150,200J |
| Charge Time | 8 sec.to 150J |
| 10 sec. to 200 J (New battery) | |
| Analysis Time | 9 sec. |
| The maximum time from the initiation of rhythm | Less than 20 seconds |
| analysis to readiness for discharge with a new battery. | |
| The maximum time from the initiation of rhythm | Less than 25 seconds |
| analysis to readiness for discharge after 6 shocks. | |
| The maximum time from initially switching power on to readiness for discharge. | Less than 30 seconds |
| Audible Prompts | 22 audible prompts |
| Visual Prompts | LED prompts; Automatic Self-test |
| Controls | Two buttons - On/Off, Shock |
| Output Energy Accuracy | +-15% into any impedance from 25 to 1750 |
| The Maximum Voltage | 1200+-50V |
| Output disabled when the patient impedance is outside limits | 202 to 200Q |
| Battery | |
| Part No | CR123A-4x2 |
| Non-rechargeable | 2.8 Ah |
| Capacity | 100 discharges at 200 Joules or 120 discharges at 150 Joules |
| Shelf Life(25C15C) | 5 years standby (after installation) |
| Physical | |
| Dimensions | 303 x 216 x 89 mm |
| Weight | 2.0 kg |
| Operating Temperature | 0C to 40C |
| Operating Humidity | Relative humidity between 30% and 95% |
| (non-condensing) | |
| Storage Temperature | -20C to 55C |
| (without battery) | |
| Storage Humidity | Up to 93%(non-condensing) |
| (without battery) | |